Favorites Chinese

 


T-302 H.V. Surge Generator

T-302 H.V. Surge Generator is mainly used to test high resistance fault and flashover fault for power cable of 3~10kV. In conjunction with the T-903 Power Cable Fault Locator and the T-505 Pinpoint Fault Locator for fault locating. Matching with the special digital micro ammeter, T-302 can also perform Current Leakage test for cable of 6kV and below.

Specifications:

  • Output voltage: 0 ~35kV, negative polarity, adjustable continuously.
  • Nominal capacitor: 2μF
  • Charge current: ≥30mA at peak value
  • Pulse power: 900J
  • Discharge interval: 6s
  • Power: AC 220±10%, 50Hz±1%
  • Altitude: < 1000m
  • Temperature: 0 - +40℃
  • Humidity: 70% maxim at 40℃
  • Dimension: 450×370×500 mm
  • Weight: 40kg

Features:

  • To cooperate with T-903 Cable Fault Locator to locate faults, three modes selectable to suit different fault.
  • All controlling and operation buttons are on the front panel, easy to operate.
  • Easy wiring, safe operation.